AIXBOILERPRESSURE VESSELS & BOILERS Enquiry

Electric Heating Tube – Immersion Elements for Water, Oil and Steam

Electric Heating Tube – Immersion Elements for Water, Oil and Steam

The heating element is the part of an electric boiler that fails first, and it almost always fails for one of three reasons: wrong watt density, scale, or a dry start. These replacement bundles are built to the duty…

  • Built to your capacity, pressure and material requirements
  • Inspection records and export documentation
  • Spare parts and commissioning guidance
CapacityTo be confirmed against duty
MaterialCarbon steel / SS304 / SS316L / glass-lined
Design pressure0.6–2.5 MPa (as required)
ApplicationIndustrial process

Specifications can be customised. Contact us for full technical data and drawings.

  • Food and beverage industry
  • Palm oil mills and biomass processing
  • Textile, rubber and plastics
  • Chemical, pharmaceutical and paper

Replaceable flanged immersion heating elements in 316L, Incoloy or titanium, 3–36 kW per element, for boilers, tanks and thermal oil systems.

Category:

Description

The heating element is the part of an electric boiler that fails first, and it almost always fails for one of three reasons: wrong watt density, scale, or a dry start. These replacement bundles are built to the duty rather than to a catalogue number.

Selection factors

  • Medium: water, thermal oil, or steam space — each needs a different watt density.
  • Watt density: 3–6 W/cm² for water, 2–4 W/cm² for oil, lower where scale is likely.
  • Sheath material: 316L standard, Incoloy 800 for high temperature, titanium for seawater and chlorides.
  • Connection: flange DN80–DN300, threaded or clamp, with gasket and terminal cover.

Technical specification

Parameter Range
Power per element 3 – 36 kW
Voltage 220 / 380 / 400 / 415 V
Sheath 316L, Incoloy 800, titanium
Max sheath temperature 600 °C (Incoloy)
Flange DN80 – DN300, PN10 / PN16
Test Insulation resistance and hydro test per element

Replacement practice

Replace elements as a set when more than one has failed: the survivors have the same hours and the same scale history. Check the gasket seat and the flange face before refitting, and confirm the low-level and flow interlocks are working — a dry start will destroy a new bundle in minutes.

FAQ

Can you match an existing element? Yes — send the flange drawing, power, voltage and sheath material, or a photo with dimensions.

Do you supply the thermostat and contactor? Yes, as a matched control kit.

Compared with other options

Typical differences between AIXBOILER equipment and a general-market alternative.

AIXBOILERGeneral market
Manufacturing & inspectionSelected Grade-A partner factories in China, third-party inspectionUnverified sourcing / outsourced production
Efficiency on siteOptimised combustion, low excess air, tested at commissioningNameplate figure only
DocumentationDrawings, material certificates, O&M manualLimited or on request
After-salesSpare parts and engineer support, remote diagnosisVaries, often no local stock
CustomisationFuel, pressure, voltage and layout adaptedFixed catalogue models

Questions

Can the capacity be customised?

Yes. Capacity, pressure and fuel are matched to your process requirements.

What is the delivery time?

Typically 30-60 working days after drawing approval.

Is installation included?

We provide installation supervision, commissioning and operator training.

Request a Quotation

Send the duty and site conditions; our technical team will reply with a specification and price.

We reply within one working day. Your data is used only to answer this enquiry.

WA Chat on WhatsApp
WAWhatsApp ✉Email Enquiry