Description
The heating element is the part of an electric boiler that fails first, and it almost always fails for one of three reasons: wrong watt density, scale, or a dry start. These replacement bundles are built to the duty rather than to a catalogue number.
Selection factors
- Medium: water, thermal oil, or steam space — each needs a different watt density.
- Watt density: 3–6 W/cm² for water, 2–4 W/cm² for oil, lower where scale is likely.
- Sheath material: 316L standard, Incoloy 800 for high temperature, titanium for seawater and chlorides.
- Connection: flange DN80–DN300, threaded or clamp, with gasket and terminal cover.
Technical specification
| Parameter | Range |
|---|---|
| Power per element | 3 – 36 kW |
| Voltage | 220 / 380 / 400 / 415 V |
| Sheath | 316L, Incoloy 800, titanium |
| Max sheath temperature | 600 °C (Incoloy) |
| Flange | DN80 – DN300, PN10 / PN16 |
| Test | Insulation resistance and hydro test per element |
Replacement practice
Replace elements as a set when more than one has failed: the survivors have the same hours and the same scale history. Check the gasket seat and the flange face before refitting, and confirm the low-level and flow interlocks are working — a dry start will destroy a new bundle in minutes.
FAQ
Can you match an existing element? Yes — send the flange drawing, power, voltage and sheath material, or a photo with dimensions.
Do you supply the thermostat and contactor? Yes, as a matched control kit.