Biomass is the cheapest route to 300 °C process heat where wood residue is already on site. The YLW (horizontal) and YGL (vertical) are grate-fired thermal oil heaters that combine a solid-fuel furnace with a coil bundle, so the oil side sees steady heat and the fuel side handles moisture and ash.
Furnace and coil
- Chain grate for chips and pellets; fixed or reciprocating grate for PKS, husk and bagasse.
- Two or three radiant passes before the convective coil, so the oil film temperature stays within limits.
- Automatic fuel feed with a metering screw and a low-level hopper alarm.
- Ash removal by screw conveyor into a bin.
Technical specification
| Parameter | Range |
|---|---|
| Thermal capacity | 300,000 – 12,000,000 kcal/h (0.35 – 14 MW) |
| Outlet temperature | Up to 300 °C |
| Design pressure | 0.8 – 1.0 MPa |
| Efficiency | 84 – 87 % |
| Fuel | Wood chips, pellets, PKS, rice husk, bagasse |
| Fuel moisture | Up to 30 % with air preheater |
Typical installations
Plywood and particleboard presses, asphalt mixing plants, textile dyeing, and chemical reactors that need 200–300 °C oil. In plywood plants the boiler is often fed with the plant’s own trim and dust, which turns a waste stream into process heat.
Control and safety
Oil outlet temperature controls the fuel feed and the grate speed; a bypass valve protects the coil at low flow. Safety interlocks cover low oil flow, high oil temperature, low hopper level and flame failure.
FAQ
Can it burn wet chips? Up to about 30 % moisture with an air preheater; above that the furnace volume and the drying of fuel become uneconomic.
How often is ash removed? Daily for a small unit, continuously by conveyor on larger ones.