Hot water is a simpler duty than steam — no blowdown, no steam trap losses, no water-level control — but the boiler still has to match the circuit. The CWNS is atmospheric and the WNS pressurised; both are fire-tube…

  • Imetengenezwa kulingana na uwezo, shinikizo na mahitaji yako ya malighafi
  • Kumbukumbu za ukaguzi na nyaraka za mauzo ya nje
  • Vipuri na mwongozo wa uendeshaji
CapacityTo be confirmed against duty
MaterialCarbon steel / SS304 / SS316L / glass-lined
Design pressure0.6–2.5 MPa (as required)
ApplicationIndustrial process

Specifications can be customised. Contact us for full technical data and drawings.

  • Food and beverage industry
  • Palm oil mills and biomass processing
  • Textile, rubber and plastics
  • Chemical, pharmaceutical and paper

Atmospheric CWNS and pressurised WNS hot water boilers fired by gas or oil, 0.7–14 MW, 95/70 °C to 130/70 °C, for heating and process water.

Description

Maji ya moto ni wajibu rahisi kuliko mvuke – hakuna blowdown, hakuna hasara za mvuke, hakuna udhibiti wa kiwango cha maji – lakini boiler bado inapaswa kuendana na mzunguko. CWNS ni ya anga na WNS inashinikizwa; zote mbili ni miundo ya bomba la moto inayotolewa na kichomea kinacholingana, na chaguo kati yao hufuata shinikizo la mfumo na programu ya halijoto.

Anga au shinikizo

  • CWNS:upanuzi wazi, hadi 95/70 °C, rahisi na rahisi zaidi kusakinisha.
  • WNS:mzunguko uliofungwa hadi 130/70 ° C na 1.6 MPa, inahitajika kwa joto la juu na majengo marefu.

Uainisho wa kiufundi

Kigezo Kiwango
Uwezo wa joto 0.7 – 14 MW
Ugavi / kurudi 95/70 °C, 115/70 °C, 130/70 °C
Shinikizo la muundo MPa 0.1 (CWNS) – MPa 1.6 (WNS)
Ufanisi ≥ 95 % na mwanauchumi
≥ 92 % (gesi), ≥ 90 % (mafuta) Gesi asilia, LPG, dizeli, mafuta mazito
≤ 30 mg/m³ na FGR ≤ 30 mg/m³ yenye kichomeo cha chini cha NOX

Pointi za muundo wa mfumo

Boiler ya maji ya moto inahitaji kiwango cha chini cha joto cha kurudi ili kuepuka kufidia kwenye bomba la moto – kwa kawaida 60 °C kwa kurusha gesi. Ambapo mzigo unarudi baridi, valve ya kuchanganya njia tatu au pampu ya kurejesha inalinda boiler. Chombo cha upanuzi na valve ya usalama ni ukubwa kutoka kwa kiasi cha maji, sio pato la boiler.

Utumiaji

Vituo vya kupokanzwa vya wilaya, nyumba za kuhifadhi mazingira, hoteli, usindikaji wa chakula, na mchakato wowote unaohitaji maji ya 70-130 °C badala ya mvuke. Katika miradi ya retrofit boiler mara nyingi hubadilisha mfumo wa mvuke ili kuondoa hasara za mtego na kupunguza shinikizo la uendeshaji.

Maswali Yanayoulizwa Mara kwa Mara

Je, inaweza kutoa inapokanzwa na kusindika maji?Ndio, kupitia kibadilishaji joto cha sahani ambacho hutenganisha mizunguko miwili.

Ni matibabu gani ya maji inahitajika?Kulainisha kwa ajili ya kujipodoa, pamoja na kizuia ulikaji na upimaji wa mara kwa mara wa pH na upenyezaji.

Compared with other options

Typical differences between AIXBOILER equipment and a general-market alternative.

AIXBOILERGeneral market
Manufacturing & inspectionSelected Grade-A partner factories in China, third-party inspectionUnverified sourcing / outsourced production
Efficiency on siteOptimised combustion, low excess air, tested at commissioningNameplate figure only
DocumentationDrawings, material certificates, O&M manualLimited or on request
After-salesSpare parts and engineer support, remote diagnosisVaries, often no local stock
CustomisationFuel, pressure, voltage and layout adaptedFixed catalogue models

Questions

Can the capacity be customised?

Yes. Capacity, pressure and fuel are matched to your process requirements.

What is the delivery time?

Typically 30-60 working days after drawing approval.

Is installation included?

We provide installation supervision, commissioning and operator training.